Vacuum Pump - Diffusion Pump – AX-65 / HS-2 / VHS-4 / VHS-6
|
Pump Model
|
AX-65
|
HS-2
|
VHS-4
|
VHS-6
|
Previous Model Number
|
-
|
0160
|
0183
|
184
|
Speed, l/s (operating range)
|
|
|
|
|
Air
|
65
|
160
|
750
|
1,550
|
Helium & Hydrogen
|
90
|
200
|
940
|
1,930
|
Maximum forepressure, Torr (mbar)
|
|
|
|
|
No load
|
0.75 (1.00)
|
0.55 (0.72)
|
0.65 (.86)
|
0.65 (0.85)
|
Full load
|
0.60 (0.78)
|
0.40 (0.52)
|
0.55 (.73)
|
0.55 (0.72)
|
Maximum throughput,
|
|
|
|
|
T-l/s (mbar-l/s) In operating range
|
0.19 (0.25)
|
0.60 (0.80)
|
1.5 (2.0)
|
2.4 (3.2)
|
@ 1 x 10-2 Torr (1.3 x 10-2 mbar)
|
0.30 (0.40)
|
0.70 (0.93)
|
2.5 (3.2)
|
3.5 (4.5)
|
Minimum recommended backing pump
for maximum throughput, cfm (m3/hr)
|
0.15 (0.25)
|
5.0 (8.5)
|
10 (17)
|
17.0 (28.9)
|
Backstreaming rate at inlet flange
mg/cm2/min (standard cold cap)*
|
2 x 10-4
|
1 x 10-3
|
5 x 10-4
|
5 x 10-4
|
Warmup time, minutes
|
7
|
15
|
10
|
10
|
Cooldown time, minutes
With quick cool coil, where applicable
|
-
|
10
|
10
|
10
|
Fluid charge
|
30cc
|
100 cc
|
300 cc
|
500 cc
|
Electrical requirements
|
1 ph
50/60 Hz
90/115/165/220 V
|
1 ph
50/60 Hz
120/240 V
|
1 ph
50/60 Hz
120/208/240 V
|
1 ph
50/60 Hz
120/208/240 V
|
Power, Watts
|
200/250
|
450
|
1450
|
2200
|
Cooling water, U.S. gpm (l/hr)
at 60-80° F (15-26 °C)
|
N/A
|
0.1 (20)
|
0.15 (30)
|
0.25 (50)
|
|
|