Model Number
|
Specifications
|
Power Supply
|
Features
|
Innova-Sonic 205
Clamp on type.
Ultrasonic Transit-Time
Clamp on & Insertion Flow Meter.
|
*Fluid:liquids with a small quantity of air bubbles or suspended solids.
*Temperature:
Transmitter:-40~60℃.
transducer:
-Clamp on: -40~80℃.
(High temp.: -40~170℃)
-Insertion: -40~80℃.
(High temp.: -40~150℃)
*Accuracy:±0.5 % of reading.
*Repeatability: ±0.5% of reading.
*Pipe Size:1”~200”(25mm~5m).
*Flow Range:0~±40 ft/s(0~±12 m/s).
|
90~250 VAC, 48~63 Hz and 10~36 VDC.
|
*Clamp on sensor require no pipe cutting or process interruption and no plant shut-down.
*Available with standard insertion transducers or small(0.75” diameter) insertion transducers for pipes smaller than 16”(DN400)
*Offers low power consumption, high reliability, and outstanding applicability.
Insertion type.
|
Output signal
|
0/4~20 mA
Pulse
Relay
RS-232
RS-485
|
Model Number
|
Specifications
|
Power Supply
|
Features
|
205 Thermal Energy
Ultrasonic Thermal Energy Meter.
|
*Fluid: For liquid heating and cooling applications.
*Temperature:
Transmitter:-40~60℃.
transducer:
-Clamp on: -40~80℃.
(High temp.: -40~170℃)
-Insertion: -40~80℃.
(High temp.: -40~150℃)
*Accuracy:±0.5% of reading.
*Repeatability: ±0.5% of reading.
*Pipe Size:1”~200”(25mm~5m).
*Flow Range:0~±40 ft/s(0~±12 m/s).
|
90~250 VAC, 48~63 Hz and 10~36 VDC
|
*Measurement of energy rate and totalized energy consumption.
*Clamp on sensor mean no pipe break or process interruption and offer low installation effort and costs.
*Suitable for virtually any liquid heating and cooling application including HVAC, office buildings, large condominium or apartment developments, thermal solar heating and geothermal applications.
*Includes two PT100 resistance temperature detectors (RTD’S) for measuring inlet and outlet temperature.
|
Output signal
|
0/4~20 mA
Pulse:
0~9999 Hz, OCT
Relay: SPST
|
Model Number
|
Specifications
|
Power Supply
|
Features
|
Innova-Sonic 206
In-Line Transit-Time Ultrasonic Flow Meter
|
*Fluid: liquids with a small quantity of air bubbles or suspended solids.
*Temperature: Fluid:-40~80℃.
*Flow Range:0 ~ 23ft/s(0 ~ 7 m/s).
*Pipe Size:1”~10”(25mm~250mm).
*Accuracy:±0.5% of reading.
*Repeatability: ±0.2% of reading.
|
90~250 VAC, 48~63 Hz and 12~36 VDC.
|
*Ultra-precise patented time measurement technology measures the transit-time accurately between the upstream and downstream transducers.
*Power coated Carbon Steel(150# ANSI or DN PN10)
*Our patented ultra precise PicoFlyTM measurement technology allow ultrasonic transit time of flight samples to be measured in picoseconds 10-12 for superb resolution and tremendous low flow detection rather than typical nanoseconds 10-9.
|
Output signal
|
0/4~20 mA.
Pulse.
Relay: SPST.
RS-232.
|
Model Number
|
Specifications
|
Power Supply
|
Features
|
Innova-Sonic 210
Portable Ultrasonic Flow meter with Bluetooth® Wireless.
|
*Fluid: liquids with a small quantity of air bubbles or suspended solids.
*Temperature:
Transmitter:-40~60℃
Transducer:-40~80℃
*Flow Range: 0~±40 ft/s(0~±12 m/s)
*Pipe Size:1”~200”(25mm~5m
*Accuracy:±0.5% of reading.
*Repeatability: ±0.5% of reading.
|
12 VDC(10~36 VDC) Battery power(main and spare batter are respectively 8 hr).
|
*Palm® TX PDA interface with Bluetooth® wireless.
*Clamp on sensor require no pipe cutting or process interruption and no plant shut-down.
*Magnetic sensor clamping fixture with slip-scale gage.
*Battery power supply with battery recharge port.(including spare battery)
*Hygienic measurement, no risk of contamination, suitable for ultra clean liquids.
|
Output signal
|
4-20 mA.
Pulse.
Relay.
|