Model Number
|
Specifications
|
Power
|
Connectable gauges
|
Feature
|
XGS600
|
*LCD Display
*Range:1x10-11 Torr to ATM.
*Temperature:
5~40℃.
|
*100~240VAC,2A,50/60 Hz.
|
* 4 hot filament plus 4 convection gauge.
* 5 inverted magnetron gauges.
* 12 convection gauges.
|
*Easy to use: can be operated without a manual; screens and menus are easy to follow.
*Easy to order: only 3 different controller gauge cards/modules to choose from.
*Practical: just takes a few minutes to add or remove a gauge card
*Convenient: view up to 8 gauges at one time or change the font to view 2 from 15 feet away.
|
Output
|
*1V/DEC LOG,
0-10V FS.
*RS-232 & RS-485 digital communications.
|
Model Number
|
Specifications
|
Power
|
Connectable gauges
|
Feature
|
AGC100
AGD100
AGC100
|
*1 channel.
*LED Display
*Range:2x10-10~
1500 mbar.
*Unit:mbar,Torr,
Pascal.
*Temperature:
0~50℃.
|
*90~250 V,50/60 Hz,≦30W
|
*AGC100:
FRG,PVG,PCG,CDG.
*ACD100:
FRG,PVG,PCG
|
*Ease of setup.
* Global compatibility.
* Utilize pressure readings to perform critical operations.
AGD100
|
Output
|
*0-10.3V
*1 setpoint relay.
*RS-232 C digital interface.
*D-Sub 9 pin connector.
|
Model Number
|
Specifications
|
Power
|
Connectable
gauges
|
Feature
|
BRAX3000
|
*LCD setup screen.
*Range:1.3x10-9~1333 mbar.
*Temperature:
Operating:
0~40℃.
Storage:
-40~70℃.
*Cable length:
10~50 ft
|
*100~240 VAC,
50/60 Hz.
*3000: one alternate analog input(0-10V) from CDG.
|
*Two convention gauge and one Ionization gauge.
|
* Significant cost saving using a different approach to traditional full range vacuum measurements.
* Low heat generating, compact space saving half rack design, bench top or panel instrument
* Alternate analog input from other types of vacuum gauges such as a Capacitance Diaphragm gauge.
|
Output
|
3000:3 set point replays from CDG.
3100: 3 set point replays., one analog output from CDG.
|
Model Number
|
Specifications
|
Power
|
Connectable
gauges
|
Feature
|
VGC301
|
*LCD Display.
*Range:1x10-4~1333 mbar.
*Temperature:
Operating:
0~40℃.
Storage:
-40~70℃.
*Cable length:
50~100 ft.
|
*100~240 VAC,
50/60Hz. *12~30VDC.
*two signal-pole double-throw relays(SPDT)
|
*One convection gauge.
*Connects:
-Gauge:9 pin D, Female.
-Analog output and digital interface:9 pin D male.
|
*Remote Panel mount or bench top controller for the Convection vacuum gauge tubes.
* Wide measuring range lets you monitor your vacuum system with a single gauge.
* Includes two setpoints, user-selectable analog output
*Analog output is configurable as a non-linear S-curve, log-linear, or user-scalable linear.
|
Output
|
*0.375~5.659VDC
*0~10 VDC
*1~8VDC,1V/decade.
*Digital interface:
RS-232 & RS485.
|
Model Number
|
Specifications
|
Power
|
Connectable
gauges
|
Feature
|
RGC150
|
*LED Display.
*Range: 1x10-3~
1013 mbar.
*Fitting:1/8” MNPT
*Cable length:10~40 ft.
|
*100~240 VAC,50/60 Hz
*Setpoint controls:7A,250V
|
*With 531 TC Gauge tube.
*Replacement sensors:
1/8” MNPT, KF16,KF25,
CF16(1.33”)
|
*Two easily configured set points.
*Utilize pressure readings to perform critical operations.
*Monitor vacuum performance from a remote location.
|
Output
|
*0-5 VDC
*RS-232 communication interface.
|
Model Number
|
Specifications
|
Power
|
Connectable
gauges
|
Feature
|
RGC100
|
*LED Display.
*Range:1x10-3~
1000 mbar
*Fitting:1/8” MNPT
*Cable :10~40 ft.
|
*100~240 VAC,50/60 Hz
*Setpoint controls:7A,250V
|
*With 531 TC Gauge tube.
*Replacement sensors:
1/8” MNPT, KF16,KF25,
CF16(1.33”)
|
*No calibration required at initial setup.
*Easily read from across a room, or in dimly lit locations.
*Shock resistant and requires infrequent calibration.
|
Output
|
*0-5 VDC
*RS-232 communication interface.
|
Model Number
|
Specifications
|
Power
|
Connectable
gauges
|
Feature
|
801
|
*Range:1x10-3~
2 Torr.
*Temp.:10~40℃
*Cable:10 ft
|
*120V,60Hz
*230V,50 Hz
|
531 and 536
Gauge tube.
|
*Provides repeatable and stable pressure measurements from a thermocouple gauge tube.
|
Output
|
*0~11 Mv
*Non-linear, monotonic.
|
Model Number
|
Specifications
|
Power
|
Connection
|
Feature
|
CVC3000
|
*Range:0.1~1080
Mbar.
*Temp.:
Storage:-10~60℃
Operation:10~40℃
*Cable:2m
|
100~230 V,
50/60 Hz
|
*PTFE-tubing conn.
*10/8 mm with hose nozzle DN6/10mm,
KF DN 16.
|
*Controls process vacuum, cooling water and venting to demand.
*Interactive communication through RS232C serial interface.
*Self-configuring by recognizing any VACUU.BUS appliance: NT VARIO pumps, valves, external gauge heads.
|
Principle
|
Capacitive, gas type independent, abs. pressure
(alumina ceramics)
|
Model Number
|
Specifications
|
Power
|
Connection
|
Feature
|
VNC2
|
*Range:1~1100 mbar.
*Temp.:
Storage:-10~60℃
Operation:10~40℃
Continuous operation:
40℃(Max)
*Short time:
80℃(Max)
|
100~230 V,
50/60 Hz
|
*PTFE-tubing conn.
*10/8 mm with hose nozzle DN6/10mm,
KF DN 16.
|
*On- demand control of process vacuum, cooling water and venting.
*easy reset of programmed pressure during operation.
*Automatic or manual setting of the pressure switching interval.
|
Principle
|
Capacitive, gas type independent, abs. pressure
(alumina ceramics)
|