Model Number
|
Specifications
|
Input Power
|
Features
|
Smart-Trak 50
Economical
OEM Digital Mass
Flow Controller
|
*Gas: All neutral,
non-contaminated dry and
clean gases.
*Flow Range: 0.02~50 slpm
*Max pressure: 145 psig.
*Temperature: 0-50℃
*Response time: 300 ms
*Accuracy: ±1.5% of F.S
*Repeatability: ±0.25% of F.S
|
Meter:15 or 24 VDC
Controller:24 VDC,
RS-485
|
*7 measurement range of- the-shelf
*Advanced 316SS platinum sensor technology and patented LFE
provide.Excellent linear performance.
*LCD Display and digital setpoint control with optional analog setpoint/output signal.
|
Output signal
|
RS-232,
RS-485
4-20 mA
0-5 VDC
|
Model Number
|
Specifications
|
Input Power
|
Features
|
Smart-Trak2 100
Next Generation High performance Digital Gas Mass Flow Meters and
Controllers.
|
*Gas: All clean gases including corrosives & toxics.
*Flow Range:
10 sccm~1000 slpm。
*Max pressure: 500 psig.
*Temperature: 0-50℃.
*Response time: 300 ms.
*Accuracy: ±1% of F.S.
*Repeatability: ±0.2% of F.S.
|
Meter: 15-24 VDC
Controller: 24 VDC
|
*With Dial-A-Gas technology, you select from up to ten
pre programmed
gases or substitute your own.
*Unique pilot module lets you view and change critical control.
*316 SS Construction.
|
Output signal
|
RS-232
RS-485
0/1-5 VDC
0-10 VDC
4-20 mA
|
Model Number
|
Specifications
|
Input Power
|
Features
|
Micro-Trak 101
Ultra Low Flow High Performance Digital Gas Mass Flow Meters & Controllers
|
*Gas: All clean gases including
corrosives & toxics.
*Flow Range: 0.1~4 sccm.
* Max pressure: 500 psig.
*Temperature: 0-50℃.
*Accuracy: ±1% of F.S
*Repeatability: ±0.2% of F.S
|
Meter: 15-24 VDC
Controller: 24 VDC
|
*Digital performance including
Dial-A-Gas multi-gas capability
that enables use with 10 different
gases.
*Unique pilot module lets you view and change critical control.
*316 SS Construction.
|
Output signal
|
RS-232,
Pilot Module
4-20 mA
0/1-5 VDC
0-10 VDC
|
Model Number
|
Specifications
|
Input Power
|
Features
|
Max-Trak 180
NEMA 6/IP67 Compliant Industrial Mass Flow Meters and Controllers for Gases
|
*Gas: All clean and dry gases
including corrosives.
*Flow Range:
10 ~1000 slpm.
*Max pressure:500 psig.
*Temperature:
Gas: 0~50℃
Ambient: -20~50℃
*Accuracy: ±1% of F.S.
*Repeatability: ±0.2% of F.S.
|
Meter:15-24VDC
Controller:24 VDC
|
*Industry’s only NEMA6/IP67 industrial MFC affords wash down protection eliminating the need for secondary enclosures.
*Dial-A-Gas technology
*Operation at low differential pressure possible due to powerful direct valve design.
|
Output signal
|
RS-232
4-20mA
1/0-5VDC
0-10VDC
|
Model Number
|
Specifications
|
Input Power
|
Features
|
Max-Trak 180 + Flange
Industrial Mass Flow Meters & Controllers with Stainless steel Flange
|
*Gas: All clean gases including
toxics and corrosives.
*Flow Range:
100 ~1000 slpm
*Max pressure:500 psig.
*Temperature:
Gas: 0~50℃
Ambient: -20~50℃
*Accuracy: ±1% of F.S
*Repeatability: ±0.2% of F.S
|
Meter:15-24VDC
Controller:24 VDC
|
*Industry’s only NEMA6/IP67
industrial MFC affords wash down protection eliminating the need for secondary enclosures.
*Dial-A-Gas technology
*Both ANSI & DIN Flanges available
in various sizes and pressure
ratings;316 SS Construction.
|
Output signal
|
RS-232,
RS-485
4-20mA,0-5VDC,
0-10VDC,1-5VDC
|
Command Signal
|
4-20mA,0-5VDC,
0-10VDC,1-5VDC
RS-232,RS-485 MODBUS
|
Model Number
|
Typical Applications
|
Power Requirement
|
Features
|
Compod for 100 series
Advanced Automation
for SIERRA 100
Series Instruments.
|
*Process Monitoring.
*Leak Testing.
*Gas Mixing and Blending.
*Batching.
|
24 VDC
|
*RS-485 Communication with MODBUS RTU protocol allows digital multi-drop networks.
*Two digital outputs and one analog input can be configured by user with MODBUS or included software for a wide variety of process controls.
*Available with optional LCD display.
|
Inputs
|
RS-485 MODBUS RTU.
0-10V.
0-20 mA.
|
Output
|
RS-485.
MODBUS RTU,
Optically Isolated.
Analog Pluse.
|